BECKMAN COULTER INC

ACCESS 2 · Hematology

510(k): 2 Recall: 11 UDI: 1 MAUDE: 10 Class.: 56

Recalls (11)

2026-09-02

Beckman Coulter has identified a software issue affecting DxC 500i Clinical Analyzers when testing plasma samples. Following user configuration of a Clinical Chemistry test to use units different from the system default, a subsequent configuration change and activation of the draft configuration in the System Configuration page may cause the analyzer to revert the test units to the system default …

2025-09-19

Beckman Coulter has confirmed a software anomaly on DxI 9000 Access Immunoassay Analyzer and the DxC 500i Clinical Analyzer that may prevent correct application of user-specified manual dilution factors when ordering additional tests for samples already "In Progress" using the same "Sample ID number". This can lead to false low or high patient results and potential delays in reporting, risking err…

2017-11-06

Potential for minor skin burn if the tool contacts the reagent storage interface board (B79917) when performing a pipettor alignment.

2014-10-06

Beckman Coulter is recalling the Small Form Factor Console PC (SFF PC) (B23083) for use with the Access 2 Immunoassay systems because it may experience a "MFC Exception" error during normal operation of the Access 2 Immunoassay Systems.

2012-11-01

It has been determined that, in some cases, pulley drive components have broken parts or have become loose, mispositioned, or disconnected from their drive shafts. When these defects occur, the pulley may not turn at all, or may turn at an incorrect speed, resulting in inadequate washing or mixing of the contents of the reaction vessel.

2010-08-13

This recall was initiated because Beckman Coulter has received reports of erroneous test results being reported as a result of assay reagent packs being transferred between systems. Erroneous results will be generated as a result of missing or incorrect assay reagents. In these cases both false positive and false negative results are possible, depending upon the assay configuration.

2003-01-30

False results from secondary pour off tubes

2003-01-30

False results from secondary pour off tubes

UDI Registrations (1)

DxC 500i Clinical Analyzer, DxC 500i Access 2 Immunoassay Module

The DxC 500i Clinical Analyzer combines the DxC 500 AU Clinical Chemistry Analyzer and the Access 2 Immunoassay System into a single instrument presentation. The system is for in vitro diagnostic use only. The chemistry module of the DxC 500i Clinical Analyzer is an automated chemistry analyzer that measures analytes in samples, in combination with appropriate reagents, calibrators, quality contr…

MAUDE Adverse Events (10)

Malfunction
20080214
Malfunction
20080214
Malfunction
20080212
Malfunction
20080207
Malfunction
20080206
Malfunction
20080201
Malfunction
20080130
Malfunction
20080130
Malfunction
20080124
Malfunction
20080123

FDA Classification (56)

Assay, Heparin

Hematology

Adamts13 Activity Test System

Hematology

Stain, Papanicolau

Hematology

Tablet, Resazurin

Hematology

Solution, Silver Carbonate

Hematology

Ethyl Eosin

Hematology

Lymphocyte Separation Medium

Hematology

Microscope, Automated, Image Analysis, Operator Intervention

Hematology

Test, Sickle Cell

Hematology

Nigrosin

Hematology

Control, Platelet

Hematology

Oxyhemoglobin

Hematology

Plasma, Coagulation Control

Hematology

Indigocarmine

Hematology

Antithrombin Iii Quantitation

Hematology

Dna-Probe, B And T Lymphocyte

Hematology

Stains, Chemical Solution

Hematology

Neutral Red

Hematology

Reagent, Schiff

Hematology

Reagent, Russel Viper Venom

Hematology

Romanowsky Stains

Hematology

Centrifuge, Microsedimentation

Hematology

Giemsa Stain

Hematology

Adenine Nucleotide Quantitation

Hematology

Stains, Microbiologic

Hematology

Separator, Automated, Blood Cell, Diagnostic

Hematology

Centrifuge, Cell-Washing, Automated For Immuno-Hematology

Hematology

Analyzer, Chromosome, Automated

Hematology

Immunohistochemistry Reagents And Kits

Hematology

Products, Red-Cell Lysing Products

Hematology

Carbol Fuchsin

Hematology

Counter, Differential Cell

Hematology

Control Material, Blood Circulating Epithelial Cancer Cell

Hematology

Hemoglobinometer

Hematology

Crystal Violet For Histology

Hematology

Warmer, Blood, Non-Electromagnetic Radiation

Hematology

System, Automated Platelet Aggregation

Hematology

Whole Blood Hemoglobin Determination

Hematology

Jenner Stain

Hematology

Red-Cell Count By Photometry

Hematology

Stains, Heinz Body

Hematology

Fluid, Diluting, Red-Cell

Hematology

Reagent, Thromboplastin And Control

Hematology

Hematoxylin, Chrome Alum

Hematology

Reagent & Control, Partial Thromboplastin Time

Hematology

Hemoglobin For Donor Testing

Hematology

Carmine

Hematology

Bothrops Atrox Reagent

Hematology

Vitamin K Epoxide Reductase Complex Subunit One (Vkorc1) Genotyping System

Hematology

Auramine O

Hematology

Assay, Glycosylated Hemoglobin

Hematology

Mucicarmine

Hematology

Control, Hemoglobin

Hematology

Red-Cell Indices, Measured

Hematology

Blood Establishment Computer Software And Accessories

Hematology

Van Gieson'S Picro-Fuchsin

Hematology